Heat Loss Calculator

Calculate the heat loss (power requirement in watts) through walls, windows, and roof, based on area, U-value, and the temperature difference between inside and outside.

Total power requirement
Embed on your website →

How to use the calculator

  1. Enter area and U-value for walls, windows, and roof (find the U-value in building plans or product datasheets).
  2. Enter the desired indoor temperature and a design outdoor temperature (e.g. the coldest typical winter day where you live).
  3. See the total power requirement in watts.

How it's calculated

Power = U × area × temperature difference, summed per building component

This is the standard building physics formula for transmission loss (heat leaking out through building components). Each component has its own U-value (lower is better insulated) and contributes to total heat loss in proportion to its area and the indoor-outdoor temperature difference.

Limitations: Only calculates transmission loss through the three given surfaces — doesn't include air leakage (infiltration), floor-to-ground loss, or ventilation heat loss, which also contribute to a building's real heating demand.

Thermal bridges — what the U-value misses

A U-value describes heat loss through a notional, homogeneous surface. Real constructions are not homogeneous: studs in an insulated wall, joists through a roof, and junctions at windows, corners and foundations all conduct heat faster than the insulation around them. These thermal bridges are not included in the element's U-value, and together they can account for a noticeable share of the real heat loss.

The consequence is that a calculation based on U-values alone paints too optimistic a picture. It remains useful — particularly for comparing options, such as how much replacing windows is worth against adding loft insulation — but it should be read as a lower bound on heat loss rather than as a precise energy calculation. Air leakage, which is also excluded, pulls in the same direction.

Frequently asked questions

What is a U-value?

The U-value measures how much heat passes through a building component per square meter and per degree of temperature difference — lower U-value means better insulation. The unit is W/m²K.

How do I find my house's U-value?

Building plans, energy certificates, or insulation/window product datasheets often state the U-value directly. The calculator's default values are typical for well-insulated, modern buildings — older buildings often have higher (worse) U-values.

Can I use this to size a heat pump or electric heater?

It gives a good starting point for transmission loss, but remember the limitations above (air leakage and ventilation aren't included) — consider adding a safety margin, or have a professional do a full energy calculation.

Embed this calculator on your website

Copy the code below to show this calculator directly on your blog or website — completely free.